LUTZ Durchflussmesser für Öl, Benzin, Aceton, Styrol | EX-geschützt
PREIS ANFRAGEN

Mit * gekennzeichnete Felder sind Pflichtfelder.
LUTZ PUMPS, INC. | USA
Family business since 1954
info@lutzpumpsamerica.com
800 8 43 39 01 (toll free)
Flow Meter TS Type LM10 Ex

Flow Meter TS Type LM10 Ex

for solvents, oils and flammable liquids

Preis anfragen

Mit * gekennzeichnete Felder sind Pflichtfelder.
  • US-0231-020
  • upon request
  • The Flow meter is suitable for the explosion hazardous area ( Atex area )
Description: The first flowmeter with touchscreen display and backlight impresses with its...more
Product information "Flow Meter TS Type LM10 Ex"

Version: without Volume preselection (Ex relay module)
Note: The Flow meter without volume preselection consists of the parts basic meter (measuring unit) and operating unit (display)

 


Description:

The first flowmeter with touchscreen display and backlight impresses with its simple, on-demand display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables accurate measurement of the volume flow and measures solvents and highly flammable liquids, oils and neutral media precisely, quickly and, above all, efficiently. Optionally, the desired volume can be preselected with the volume preselection (relay module), so that the pump or the system switches off automatically after the selected volume. This further simplifies and secures the operation of the systems.

  • Optionally with quantity preselection (relay module)
  • Media examples: Methanol, petrol, isopropanol, kerosene, formic acid, acetic acid, acetone, styrene, xylene, toluene, etc.
  • Mobile at a Drum pump or with dispenser connection or stationary in plant construction

Features & Advantages

  • Measurement according to the swash plate principle
  • High measuring accuracy
  • Variable display orientation
  • Touchscreen display with self-explanatory, multilingual user interface
  • Measuring range from 10 l/min- 100 l/min
  • Approved according to ATEX directive 2014/34/EU, category 2
Technical data
▼ WERKSTOFFE | MATERIAL | MATERIAAL ▼
Housing Material: PPS (Polyphenylensulfid)
Seals (material): FEP
Measuring chamber (material): LCP
Magnet: BaFe / PA / Edelstahl 1.4401
▼ FÖRDERDATEN | OPERATING DATA | SPECIFICATIES ▼
Flow volumes (up to max. GPM): 26,4
Temperature of medium (max °F): max. 284 °F
Operating pressure (max. psi): 58
Viscosity (up to max. cps)*: 2000
▼ DURCHFLUSSZÄHLER | FLOW METER | FLOWMETERS ▼
Messprinzip: Taumelscheibe
Connection: Gewinde
Inlet connection (inch): 2"
Outlet connection (inch): 1 1/4"
Messgenauigkeit kalibriert**: ± 1%
▼ EIGENSCHAFTEN | PROPERTIES | EIGENSCHAPPEN ▼
Explosion Protection: Yes
Connection: Gewinde
Protection type: IP55
Version: ohne Mengenvorwahl
Certification: ATEX Richtlinie (ATEX Richtlinie 2014/34/EU)
Type: LM10 Ex

* The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20 °C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.

** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter

Ex-protection
Swash plate
Battery
Flow Meter TS Type UN10 Ex Flow Meter TS Type UN10 Ex
for solvents, acids, alkalis, oils and...
Ex-protection
Swash plate
Battery
Flow Meter TS Type VA10 Ex Flow Meter TS Type VA10 Ex
for solvents, acids, alkalis and flammable liquids
Food
Ex-protection
Swash plate
Service & Support