Family business since 1954
International branch
info@lutzpumpsamerica.com
800 8 43 39 01 (toll free)

Flow Meter TS type ST10 with volume preset

Ideal for measuring neutral liquids. Liquid examples: Water, diesel, fuel oil, hydraulic...more
up to max. 2,000 mPas, with threaded connection

Ideal for measuring neutral liquids.

Liquid examples: Water, diesel, fuel oil, hydraulic oil, etc.

Features:

  • Measuring via nutating disc
  • Mobile installed on a drum pump or for stationary use in plant construction
  • For thin-bodied up to medium-viscous liquids
  • Touch screen display with self-explanatory, multilingual user interface
  • Range of measurement from 2.6 GPM (10 l/min) up to 31.7 GPM (120 l/min)
  • In plastic (PPO) 
  • Unmistakeable plug connections

Benefits:

  • Intelligible handling
  • Precise measuring results
  • Simple, modular construction
  • Easy handling
  • User-error protection
  • Reliable operation
  • Easy and unmistakeable assembly

Volume preset: 
The preselected volume is filled by pressing a key. Volume preset is possible only when relay module is connected

Explosion Protection: not explosion-proof
PURE version: without PURE version
Volume preselction: with volume preselction
  Flow meter type  ST10 / RM10 230 V Field of application Neutral...
  Flow meter type ST10 / RM10 230 V
Field of application Neutral liquids like water, mineral oils
Flow rate min. 10 up to max. 100 l/min*
Temperature max. 60 °C
Range of viscosity 2,000 mPas
Operating pressure max. 4 bar
Accuracy ± 1% standard
< 1% with adjustment to application
conditions
Inlet port G 2 outer thread to fit connector with union nut
Outlet port G 1 1/4 outer thread
LCD display Touch-Screen 63x63 mm, 128x128 pixels, display sub-total and total volume can be reset
Menue language DE, GB, ES, FR, IT, NL, PT, RU 
Materials:
Housing
Measuring chamber
Seals
Magnet
PPO
PPO/PPS
FPM
BaFe / PA / Stainless steel 1.4401
Protection type IP 55
Weight 1.6 kg
 
Relay module RM10m
Voltage 220-230 V
Frequency 50-60 Hz
Switching outputs 2 NO (potentially bound)
Output 1 (pump) 8 A, cos > 0,7
Output 2 (Valve) 0.5 A
 
* Short-time 120 l/min.