window.ga=window.ga||function(){(ga.q=ga.q||[]).push(arguments)};ga.l=+new Date; ga('create', 'UA-1314708-3', 'auto'); ga('require', 'GTM-M2BXSQ5'); ga('set', 'forceSSL', true); ga('set', 'anonymizeIp', true); ga('require', 'displayfeatures'); ga('require', 'cleanUrlTracker'); ga('require', 'outboundLinkTracker'); ga('require', 'ec'); ga('send', 'pageview'); ga('set', 'nonInteraction', true); setTimeout("ga('send', 'event', 'read', '20 seconds')", 20000); Flow meters, flow meters for petrol, oil - EX-protected
Lutz Pumps, Inc. | USA
Family business since 1954
info@lutzpumpsamerica.com
(800) 8 43 39 01 (toll free)

Flow Meter TS type LM10 With Ex volume preset

  • 0231-023
Ideal for measuring solvents and many other easy flammable liquids, oils and neutral liquids....more
Product information "Flow Meter TS type LM10 With Ex volume preset"
up to max. 2,000 mPas, with threaded connection

Ideal for measuring solvents and many other easy flammable liquids, oils and neutral liquids.

Liquid examples:

Methanol, gasoline, isopropanol, kerosene, formic acid, acetic acid, acetone, styrol, xylene, toluol, etc.

Features:

  • Mobile installed on a drum pump or stationary in plant construction
  • Measuring via nutating disc
  • For thin-bodied up to medium-viscous liquids
  • Touch screen display with self-explanatory, multilingual user interface
  • Range of measurement from 10 l/min up to 120 l/min
  • In plastic (PPS)
  • Approved according to ATEX Directive 2014/34/EU, Category 2

Benefits:

  • Intelligible handling
  • Precise measuring results
  • Simple, modular construction
  • Basis flow meter electrically conductive
  • Simple calibration
  • User-error protection
  • Reliable operation
  • Easy and unmistakeable assembly

Volume preset:
The preselected volume is filled by pressing a key. Volume preset is possible only when relay module is connected

Fragen und Antworten mehr
Hier finden Sie die häufigsten Fragen und die dazugehörigen Antworten zu diesem Artikel.
Eine Frage zum Artikel stellen

Die mit einem * markierten Felder sind Pflichtfelder. Die E-Mail wird nicht veröffentlicht.

Vielen Dank für das Stellen einer Frage. Wir werden versuchen, diese schnellstmöglichst zu beantworten.
Type LM10 / Ex-RM10mK Field of application Solvents and many other highly...
Type LM10 / Ex-RM10mK
Field of application Solvents and many other highly inflammable liquids, oils and neutral media.
Flow rate min. 10 - max. 100 l/min*
Temperature max. 40 °C
Viscosity range 2,000 mPas
max. operating pressure 4 bar
Accuracy +- 1%
<1% bei Anpassung an die Einsatzbedingungen
Inlet connection G 2 male thread suitable for connection piece with union nut
Outlet connection G 1 1/4 male thread
LCD display touch screen 63x63 mm, 128x128 pixels, display of individual and total quantity resettable
Menu language DE, GB, ES, FR, IT, NL, PT, RU
Materials
:HousingMeasuring chamberSealsMagnet

PPSLCPFEPBaFe


/ MS / stainless steel 1.4401


Identification
:Operating unitBase counter
II 2G Ex ib IIB T4 Gb**II
2G T4 Gb
Protection class IP 55
Weight 4.3 kg
Relay module Ex-RM10mK
Voltage 220-230 V
Frequency 50-60 Hz
Switching outputs 2 NO contacts (potential-bound)
Output 1 (pump) 5 A
Output 2 (valve) 0,315 A
Identification II 2G Ex eb mb [ib] IIC T4 Gb
*Shortly 120 l/min.
**Ignition protection type II 2G Ex ib IIC T4 Gb on request