Version: without Volume preselection (Ex relay module)
Note: The Flow meter without volume preselection consists of the parts basic meter (measuring unit) and operating unit (display)
Description:
The first flowmeter with touchscreen display and backlight impresses with its simple, on-demand display and operability, multilingual interface and compact design. Due to the rotating swash plate and a magnet it enables the exact measurement of the volume flow and measures solvents, acids, alkalis, easily inflammable liquids, oils and neutral media precisely, quickly and above all efficiently. Optionally, the desired volume can be preselected with the volume preselection (relay module), so that the pump or the system switches off automatically after the selected volume. This further simplifies and secures the operation of the systems.
- Optionally with quantity preselection (relay module)
- Media examples: Methanol, petrol, isopropanol, kerosene, formic acid, acetic acid, acetone, styrene, xylene, toluene, etc.
- Mobile at a Drum pump or with dispenser connection or stationary in plant construction
Features & Advantages
- Measurement according to the swash plate principle
- High measuring accuracy
- Variable display orientation
- Touchscreen display with self-explanatory, multilingual user interface
- Measuring range from 10 l/min- 100 l/min
- Approved according to ATEX directive 2014/34/EU, category 2
Housing Material: | Edelstahl (1.4581/1.4571) |
Seals (material): | FEP |
Measuring chamber (material): | Edelstahl (1.4581/1.4571) |
Magnet: | PTFE (Polytetrafluorethylen) gekapselt |
Flow volumes (up to max. GPM): | 26,4 |
Temperature of medium (max °F): | max. 284 °F |
Operating pressure (max. psi): | 145 |
Viscosity (up to max. cps)*: | 5000 |
Messprinzip: | Taumelscheibe |
Connection: | Gewinde |
Inlet connection (inch): | 1 1/4" |
Outlet connection (inch): | 1 1/4" |
Messgenauigkeit kalibriert**: | ± 1% |
Explosion Protection: | Yes |
Connection: | Gewinde |
Protection type: | IP55 |
Version: | ohne Mengenvorwahl |
Certification: | ATEX Richtlinie (ATEX Richtlinie 2014/34/EU) |
Type: | VA10 Ex |
* The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20 °C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil. ** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter