Version: without Volume preselection (relay module)
Note: The connection to the Pump tube or the system is made with a thread
Description:
The first flowmeter with touchscreen display and backlight impresses with its simple, on-demand display and operability, multilingual interface and compact design. Due to the rotating swash plate and a magnet it enables the exact measurement of the volume flow and measures acids and alkalis, almost all solvents and easily inflammable liquids precisely, quickly and above all efficiently. Optionally, the desired volume can be preselected with the volume preselection (relay module), so that the pump or the system switches off automatically after the selected volume. This further simplifies and secures the operation of the systems.
- Optional with quantity preselection (relay module)
- Media examples: Hydrochloric acid, nitric acid, styrene, petrol, acetone etc.
- Mobile at a Drum pump or with dispensing gun connection or stationary in plant construction
Features & Advantages
- Measurement according to the swash plate principle
- High measuring accuracy
- Variable display orientation
- Touchscreen display with self-explanatory, multilingual user interface
- Measuring range from 10 l/min- 100 l/min
- Simple operation
Housing Material: | Edelstahl (1.4581/1.4571) |
Seals (material): | FEP |
Measuring chamber (material): | Edelstahl (1.4581/1.4571) |
Magnet: | PTFE (Polytetrafluorethylen) gekapselt |
Flow volumes (up to max. GPM): | 26,4 |
Temperature of medium (max °F): | 176 |
Operating pressure (max. psi): | 145 |
Viscosity (up to max. cps)*: | 5000 |
Messprinzip: | Taumelscheibe |
Connection: | Gewinde |
Inlet connection (inch): | 1 1/4" |
Outlet connection (inch): | 1 1/4" |
Messgenauigkeit kalibriert**: | ± 1% |
Connection: | Gewinde |
Voltage: | 120 |
Frequency (Hz): | 60 |
Protection type: | IP55 |
Version: | ohne Mengenvorwahl |
Type: | VA10 |
* The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20 °C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil. ** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter